Baumer Hubner HeavyDuty incremental encoders are characterized by the following excellent features:

  • Robust construction with solid light alloy housing for high vibration and shock proof protection.
  • Bearings at both ends of the shaft, where construction permits.
  • Short-circuit proof power transistors with peak currents up to 300 mA for line driving over long cables with HTL-signals or optional TTL-signals to RS-422.
  • High Electromagnetic Compatibility (EMC), tested to IEC 801-4.
  • Protection against shaft currents due to insulated ball bearings, in some devices.
  • Incremental encoders without bearings for drives with large axial play or high speeds.
  • Through-hole hollow shaft, also available in Sinus-Technology and in explosion proof execution "II 2 G EEx de IIC T6".
  • Wide range of program with standard EURO-Flange B10.
  • Rear shaft option for mounting of other devices.
  • Combinations with common shaft:
    - Incremental encoder + Incremental encoder (Twin Tacho),
    - Incremental encoder + Analog-Tacho,
    - Incremental encoder + Speed Switch.

Incremental Encoders are devices for measuring speed and position in drive technology

All Baumer Hübner devices are covered by a two-year warranty subject to the conditions of the Association of the German Electrical Engineering Industry (ZVEI).

... with own bearings
  OG 6 
Square-wave cycles per turn: 100 - 512 OG 6 Servo flange
Max. output frequency: 120 kHz Solid shaft d= 6 mm
Logic level: HTL (C), TTL, TTL (R)   
Permissible encoder temperature: -20 °C to +70 °C   
Connection: Internal connection terminals   
Weight: approx. 200 g   
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 54 Ex II 3G 3D  
  
  OG 60 • HOG 60 
Square-wave cycles per turn: max. 10,000 OG 60 HOG 60 Servo flange (OG 60)
Max. output frequency: 250 kHz Solid shaft d= 6 mm (OG 60)
Logic level: HTL (C), TTL, TTL (R) Hollow shaft with clamping ring up to d= 12 mm (HOG 60) 
Permissible encoder temperature: -30 °C to +85 °C
Connection: Plug connection High resolution    
Weight: approx. 260 g (OG 60)
approx. 250 g (HOG 60)
  
Shock resistance (6 ms): 3,000 m/s²   
Protection class: IP 65 Ex II 3G 3D    
  
  OG 70 • HOG 70
Square-wave cycles per turn: 50 - 10,000 OG 70 / HOG 70 Servo flange (OG 70)
Max. output frequency: 250 kHz Solid shaft d= 6 mm (OG 70)
Logic level: HTL (C), TTL, TTL (R) Hollow shaft up to d= 14 mm (HOG 70)    
Permissible encoder temperature: -20 °C to +85 °C
Connection: Internal connection terminals   
Weight: approx. 360 g (OG 70)
approx. 240 g (HOG 70)
  
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 66   Ex II 3G 3D  
 
  OG 71 • HOG 71 
Square-wave cycles per turn: OG 71: 100 up to 1,024
HOG 71: 64 up to 2,048
OG 71 / HOG 71 Servo flange (OG 71)
Max. output frequency: 120 kHz Solid shaft d= 6 mm (OG 71)
Logic level: HTL (C), TTL, TTL (R) Hollow shaft up to d= 14 mm (HOG 71)
Permissible encoder temperature: -20 °C to +85 °C
Connection: Internal terminal strip  
Weight: approx. 360 g (OG 71)
approx. 240 g (HOG 71)
  
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 66   Ex II 3G 3D     
  
  AHE 7AFE 7 
Square-wave cycles per turn: 60 - 5,000 AHE 7 AFE 7 Version US of OG 71/•HOG 71
Max. output frequency: 120 kHz 1/2" hollow shaft (AHE 7)
Logic level: HTL (C), TTL, TTL (R) 3/8" servo flange (AFE 7)
Permissible encoder temperature: -30 °C to +70 °C NPT 1/2" fitting
Connection: Internal connection terminals   
Weight:    approx. 240 g (AHE 7)
approx. 380 g (AFE 7)
  
  
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 56     
  
  HOG 75HOG 75 K 
Square-wave cycles per turn: 250 - 2,500 HOG 75 Through-hole hollow shaft with clamping ring up to d= 26 mm (HOG 75)
Max. output frequency: 120 kHz
Logic level: HTL, TTL Cone shaft 1:10 (HOG 75 K)  
Permissible encoder temperature: -30 °C to +85 °C   
Connection: Internal connection terminals   
Weight: approx. 320 g   
Shock resistance (6 ms): 2,000 m/s²   
Protection class: IP 56 Ex II 3G 3D    
  
  OG 8HOG 8 
Square-wave cycles per turn: 1 - 2,500 OG 8 HOG 8 EURO flange B10, solid shaft d= 11mm (OG 8)
Max. output frequency: 120 kHz Through-hole hollow shaft with clamping ring up to d= 16 mm (HOG 8)  
Logic level: HTL (C), TTL, TTL (R)
Permissible encoder temperature: -30 °C to +85 °C   
Connection: Internal connection terminals   
Weight:    approx. 700 g (OG 8)
approx. 550 g (HOG 8)
  
  
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 54   
  
  OG 9 
Square-wave cycles per turn: 1 - 1,250 OG 9 EURO flange B10, solid shaft d= 11 mm
Max. output frequency: 120 kHz High HTL output current
Logic level: HTL, TTL, TTL (R) Bearing at each end
Permissible encoder temperature: -30 °C to +100 °C   
Connection: Terminal box   
Weight: approx. 900 g   
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 55 Ex II 3G 3D  
  
  OG 90 
Square-wave cycles per turn: 1,000 - 10,000 OG 90 EURO flange B10, solid shaft d= 11 mm
Max. output frequency: 250 kHz High HTL output current
Logic level: HTL (C), TTL, TTL (R) High resolution
Permissible encoder temperature: -30 °C to +85 °C   
Connection: Terminal box   
Weight: approx. 1.5 kg   
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 55   
  
  HOG 9HOG 9 G 
Square-wave cycles per turn: 1 - 2,500 HOG 9 Hollow shaft with clamping element up to d= 16 mm
Max. output frequency: 120 kHz
Logic level: HTL, TTL, TTL (R) Option: Cone shaft 1:10
Permissible encoder temperature: -30 °C to +100 °C High HTL output current
Connection: Plug connection Bearing at each end
Weight: approx. 700 g (HOG 9) Protection against shaft currents
    approx. 1,100g (HOG 9G) Twin encoder HOG 9 G  
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 56 Ex II 3G 3D  
  
  FOG 9 
Square-wave cycles per turn: 1 - 2,500 FOG 9 EURO flange B10, solid shaft d= 11 mm
Max. output frequency: 120 kHz High HTL output current
Logic level: HTL, TTL, TTL (R) Bearing at each end
Permissible encoder temperature: -30 °C to +100 °C   
Connection: Plug connection   
Weight: approx. 860 g   
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 56 Ex II 3G 3D  
  
  POG 9  
Square-wave cycles per turn: 1 - 2,500 POG 9 EURO flange B10, solid shaft d= 11 mm
Max. output frequency: 120 kHz High HTL output current
Logic level: HTL, TTL, TTL (R) Bearing at each end
Permissible encoder temperature: -30 °C to +100 °C Twin encoder POG 9 G   
Connection: Terminal box   
Weight: approx. 1.3 kg    
Shock resistance (1 ms): 3,000 m/s²   
Protection class: IP 56 Ex II 3G 3D  
  
  POG 9 G 
Square-wave cycles per turn: 1 - 2,500 POG 9 G EURO flange B10, solid shaft d= 11 mm
Max. output frequency: 120 kHz High HTL output current
Logic level: HTL, TTL, TTL (R) Bearing at each end
Permissible encoder temperature: -30 °C to +100 °C   
Connection: Terminal box   
Weight: approx. 1.7 kg  
Shock resistance (1 ms): 3,000 m/s²   
Protection class: IP 56 Ex II 3G 3D  
  
  POG 90 
Square-wave cycles per turn: 1,024 - 10,000 POG 90 EURO flange B10, solid shaft d= 11 mm
Max. output frequency: 250 kHz High HTL output current
Logic level: HTL, TTL, TTL (R) Bearing at each end
Permissible encoder temperature: -20 °C to +85 °C High resolution
Connection: large terminal box   
Weight: approx. 1.5 kg   
Shock resistance (11 ms): 1,000 m/s²   
Protection class: IP 66 Ex II 3G 3D   
  
  HOG 10 
Square-wave cycles per turn: 1 - 2,500 HOG 10 Hollow shaft with clamping element up to d= 20 mm
Max. output frequency: 120 kHz
Logic level: HTL, TTL, TTL (R) Option: Cone shaft 1:10
Permissible encoder temperature: -40 °C to +100 °C
-50 °C to +100 °C (optional)
High HTL output current
Connection: Internal connection terminals or large terminal box Protection against shaft currents
Weight: approx. 1.6 kg Twin encoder HOG 10 G    
Shock resistance (6 ms): 2,000 m/s²   
Protection class: IP 66 Ex II 3G 3D    
  
  HOG 10 G 
Square-wave cycles per turn: 1 - 2,500 HOG 10 G Hollow shaft with clamping element up to d= 20 mm
Max. output frequency: 120 kHz
Logic level: HTL, TTL, TTL (R) Option: Cone shaft 1:10
Permissible encoder temperature: -40 °C to +100 °C
-50 °C to +100 °C (optional)
High HTL output current
Connection: Large terminal box Protection against shaft currents
Weight: approx. 2.2 kg  
Shock resistance (6 ms): 2,000 m/s²   
Protection class: IP 66 Ex II 3G 3D     
  
  HOG 100 
Square-wave cycles per turn: 1,024 - 10,000 HOG 100 Hollow shaft with clamping element up to d= 16 mm
Max. output frequency: 250 kHz
Logic level: HTL, TTL Option: Cone shaft 1:10
Permissible encoder temperature: -30 °C to +85 °C High HTL output current
Connection: Internal connection terminals or large terminal box High resolution
Weight: approx. 1.5 kg Protection against shaft currents
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 66 Ex II 3G 3D  
  
  POG 10 
Square-wave cycles per turn: 1 - 2,500 POG 10 / POG 10 G EURO flange B10, solid shaft d= 11 mm
Max. output frequency: 120 kHz High HTL output current
Logic level: HTL, TTL, TTL (R) Bearing at each end
Permissible encoder temperature: -40 °C to +100 °C
-50 °C to +100 °C (optional)
Protection against inductive shaft currents with isolated coupling (e. g. K 35)    
Connection: Large terminal box
Weight: approx. 1.6 kg Twin encoder POG 10 G     
Shock resistance (6 ms): 2,000 m/s²     
Protection class: IP 66   
Ex II 3G 3D
 
  POG 10 G 
Square-wave cycles per turn: 1 - 2,500 POG 10 / POG 10 G EURO flange B10, solid shaft d= 11 mm
Max. output frequency: 120 kHz High HTL output current
Logic level: HTL, TTL, TTL (R) Bearing at each end
Permissible encoder temperature: -40 °C to +100 °C
-50 °C to +100 °C (optional)
Protection against inductive shaft currents with isolated coupling (e. g. K 35)     
Connection: Large terminal box
Weight: approx. 2.4 kg   
Shock resistance (6 ms): 2,000 m/s²  
Protection class: IP 66   
Ex II 3G 3D  
  
  HOG 11 (Offshore) 
Square-wave cycles per turn: 1 - 2,500 HOG 11 Hollow shaft with clamping element up to d= 16 mm
Max. output frequency: 120 kHz Option: Cone shaft 1:10
Logic level: HTL, TTL, TTL (R) Protection against inductive shaft currents
Permissible encoder temperature: -30 °C to +100 °C Special corrosion protection e.g. for offshore
Connection: Large terminal box Option: Hybrid bearing
Weight: approx. 1.6 kg Option: Earthing brush for capacitive shaft currents
Shock resistance (6 ms): 2,500 m/s² Option: Heating for use down to -55°C
Twin encoder HOG 11 G
Protection class: IP 67 Ex II 3G 3D
  
  HOG 11 G (Offshore)
Square-wave cycles per turn: 1 - 2,500 HOG 11 G Hollow shaft with clamping element up to d= 16 mm
Max. output frequency: 120 kHz Option: Cone shaft 1:10
Logic level: HTL, TTL, TTL (R) Protection against inductive shaft currents
Permissible encoder temperature: -30 °C to +100 °C Special corrosion protection e.g. for offshore
Connection: Large terminal box Option: Hybrid bearing
Weight: approx. 2.2 kg   Option: Earthing brush for capacitive shaft currents
Option: Heating for use down to -55°C
Shock resistance (6 ms): 2,500 m/s²  
Protection class: IP 67 Ex II 3G 3D   
  
  POG 11 (Offshore) 
Square-wave cycles per turn: 1 - 2,500 POG 11 EURO flange B10, solid shaft d= 11 mm
Max. output frequency: 120 kHz Protection against inductive shaft currents with isolated coupling (e. g. K 35)
Logic level: HTL, TTL, TTL (R)
Permissible encoder temperature: -30 °C to +100 °C Special corrosion protection e.g. for offshore
Connection: Large terminal box Option: Hybrid bearing
Weight: approx. 1.8 kg Option: Heating for use down to -55°C   
Shock resistance (6 ms): 3,000 m/s² Twin encoder POG 11 G
Protection class: IP 67 Ex II 3G 3D  
  
  POG 11 G (Offshore) 
Square-wave cycles per turn: 1 - 2,500 POG 11 G EURO flange B10, solid shaft d= 11 mm
Max. output frequency: 120 kHz Protection against inductive shaft currents with isolated coupling (e. g. K 35)
Logic level: HTL, TTL, TTL (R)
Permissible encoder temperature: -30 °C to +100 °C Special corrosion protection e.g. for offshore
Connection: Large terminal box Option: Hybrid bearing
Weight: approx. 2.4 kg Option: Heating for use down to -55°C   
Shock resistance (6 ms): 3,000 m/s²   
Protection class: IP 67 Ex II 3G 3D   
  
  HOG 12 
Square-wave cycles per turn: 600, 1,024 HOG 12 Through-hole hollow shaft with clamping ring up to d= 45 mm     
Max. output frequency: 120 kHz
Logic level: HTL (C), TTL, TTL (R)
Permissible encoder temperature: -30 °C to +85 °C   
Connection: Cable connection   
Weight: approx. 1 kg   
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 54   
  
  HOG 131 (Offshore) 
Square-wave cycles per turn: 1,024 - 3,072 HOG 131 Through-hole hollow shaft with clamping ring up to d= 36 mm     
Max. output frequency: 120 kHz
Logic level: HTL, TTL, TTL (R)
Permissible encoder temperature: -40 °C to +100 °C   
Connection: Large terminal box   
Weight: approx. 4 kg   
Shock resistance (6 ms): 2,000 m/s²   
Protection class: IP 56 Ex II 3G 3D     
  
  EGZ 14AG 14
Square-wave cycles per turn: 250 - 2,500 EGZ 14 / AG 14 Through-hole hollow shaft up to d= 70 mm
Max. output frequency: 120 kHz Especially for lift drives
Logic level: HTL (C), TTL, TTL (R)   
Permissible encoder temperature: -30 °C to +70 °C   
Connection: Plug connection (EGZ 14)
Terminal box or plug connection (AG 14)
  
Weight: approx. 1.2 kg   
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 20, IP 54   
  
  HOG 16 
Square-wave cycles per turn: 250 - 2,500 HOG 16 Through-hole hollow shaft with clamping element up to d= 38 mm
Max. output frequency: 120 kHz
Logic level: HTL, TTL, TTL (R) High HTL output current
Permissible encoder temperature: -20 °C to +100 °C Slip-ring earthing contact  
Connection: Terminal box Option: Redundant scanning  
Weight: approx. 4 kg  
Shock resistance (6 ms): 3,000 m/s²   
Protection class: IP 66 Ex II 3G 3D  
  
  HOG 161 
Square-wave cycles per turn: 250 - 2,048 HOG 161 Through-hole hollow shaft with clamping ring up to d= 75 mm
Max. output frequency: 120 kHz
Logic level: HTL, TTL, TTL (R) Option: Redundant scanning     
Permissible encoder temperature: -20 °C to +85 °C   
Connection: Terminal box  
Shock resistance (6 ms): 1,000 m/s²  
Protection class: IP 54   
    Ex II 3G 3D  
  
  HOG 163 (Offshore) 
Square-wave cycles per turn: 250 - 5,000 HOG 163 Through-hole hollow shaft with clamping ring up to d= 75 mm
Max. output frequency: 120 kHz
Logic level: HTL, TTL, TTL (R) Insulated bearings 
Permissible encoder temperature: -30 °C to +85 °C Special corrosion protection  
Connection: Large terminal box Option: Redundant scanning  
Weight: approx. 3.5 kg  
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 56 Ex II 3G 3D  
  
  HOG 165 (Offshore) 
Square-wave cycles per turn: 250 - 5,000 HOG 165 Hollow shaft with clamping element up to d= 38 mm
Max. output frequency: 120 kHz
Logic level: HTL, TTL, TTL (R) Special corrosion protection  
Permissible encoder temperature: -30 °C to +100 °C Option: Protection against shaft currents
Connection: Large terminal box Option: Slip-ring earthing contact
Weight: approx. 4 kg Option: Redundant scanning   
Shock resistance (6 ms): 3,000 m/s²  
Protection class: IP 67 Ex II 3G 3D  
  
  HOG 22HOG 220 
Square-wave cycles per turn: HOG 22: (720 - 4,000)
HOG 220: (1,024)
HOG 22 Through-hole hollow shaft with clamping ring up to d= 115 mm  
Max. output frequency: 120 kHz
Logic level: HOG 22: HTL (C), TTL, TTL (R)
HOG 220: HTL, TTL, TTL (R)
  
Permissible encoder temperature: -30 °C to +85 °C   
Connection: Terminal box or plug connection  
Weight: approx. 8.8 kg   
Shock resistance (6 ms): 2,000 m/s²   
Protection class: HOG 22: IP 54
HOG 220: IP 56
Ex II 3G 3D    
  
 HOG 28 
Square-wave cycles per turn: 1,024 - 2,048 HOG 28 Through-hole hollow shaft up to d= 150 mm  
Max. output frequency: 120 kHz
Logic level: HTL (C), TTL, TTL (R)   
Permissible encoder temperature: -30 °C to +85 °C   
Connection: Plug connection  
Weight: approx. 20 kg   
Shock resistance (6 ms): 2,000 m/s²   
Protection class: IP 54 Ex II 3G 3D    
 
 HML 131 M 
Square-wave cycles per turn: 128 - 2,048 Hollow shaft up to d= 36 mm
Max. output frequency: 200 kHz Operable under oil
Logic level: HTL (C), TTL, TTL (R)
Permissible encoder temperature: -20 °C to +90 °C Magnetic sensing 
Connection: Special connector Redundant sensing
Weight: approx. 2.2 kg   
Shock resistance (12 ms): 2,000 m/s²   
Protection class: IP 68   
  
... without own bearings
  
 HG 6 
Square-wave cycles per turn: 100 - 512 OG 6 Servo flange
Max. output frequency: 120 kHz Hollow shaft up to d= 16 mm
Logic level: HTL (C), TTL, TTL (R) Rugged construction without own bearings for very high speeds
Permissible encoder temperature: -20 °C to +85°C
Connection: Internal connection terminals Incremental disk protected in axial and radial direction      
Weight: approx. 180 g
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 56 / IP 23 Without own bearings
  
 HG 16 
Square-wave cycles per turn: 250 - 2,500 Through-hole hollow shaft with clamping ring up to d=  45 mm
Max. output frequency: 120 kHz
Logic level: HTL, TTL, TTL (R) Axial displacement max. - 0.5 mm, +1.5 mm
Option: up to +2.5 mm  
Permissible encoder temperature: -30 °C to +100°C
Connection: Terminal box, Option: Plug connection Option: Redundant scanning     
Weight: approx. 2.4 kg   
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 56 Without own bearings
  
 HG 18HG 22 
Square-wave cycles per turn: HG 18: 250 - 2,500
HG 22: 720 - 4,000
Through-hole hollow shaft with clamping ring up to d=  110 mm
Max. output frequency: 120 kHz
Logic level: HTL (C), TTL, TTL (R) Axial displacement max. - 0.5 mm, +1.5 mm
Option: up to +2.5 mm    
Permissible encoder temperature: -30 °C to +70°C
Connection: Terminal box, Option: Plug connection Option: Redundant scanning     
Weight: HG 18: approx. 4.2 kg
HG 22: approx. 5.8 kg
  
Shock resistance (6 ms): 1,000 m/s²   
Protection class: HG 18: IP 54,
HG 22: IP 44
Without own bearings
  
 HG 21HG 211 
Square-wave cycles per turn: 2,500 HG 21 / HG 211 Through-hole hollow shaft up to d=  95 mm
Max. output frequency: 120 kHz  Option: 160 kHz
Logic level: HTL (C), TTL, TTL (R) Axial displacement max. - 0.5 mm, +1.5 mm
Option: up to +2.5 mm  
Permissible encoder temperature: -30 °C to +70 °C
Connection: Connector Option: redundant scanning    
Weight: approx. 5.8 kg   
Shock resistance (6 ms): 1,000 m/s²   
Protection class: IP 44 Without own bearings
 
 HMC 16 (M) + HEAG 158 V (M)
Square-wave cycles per turn: 128 - 8,192 HMC 16 (M) + HEAG 158 V (M) Hollow shaft up to d= 55 mm
Max. output frequency: 2,000 kHz Magnetic sensing 
Logic level: HTL, TTL
Permissible encoder temperature: -30 °C / 0 °C to +70 °C / 105 °C Redundant sensing (optional)
Connection: 12 pin mating connector (male contacts)  
Weight: approx. 2.4 kg   
Shock resistance (12 ms): 3,000 m/s²   
Protection class: HMC 16 (M) - IP 68
HEAG 158 V (M) - IP 65
  
  
MHGE 100 B5 
Square-wave cycles per turn: 64 ... 4096 MHGE 100 B5 Through-hole hollow shaft with d= 20 ... 80 mm
Logic level: HTL, TTL Large permissible axial displacement
Max. output frequency: 300 kHz Large permissible air gap tolerance
Permissible encoder temperature: -40 °C up to +100 °C Option: additional incremental signals
Connection: 12 pole flange socket (ccw, pins)  
Vibration resistance (55 Hz ... 2000 Hz): 300 m/s²   
Shock resistance (2 ms): 3.000 m/s²   
Protection class: wheel IP 68 / head IP 67    
 
MHGE 200 B5 
Square-wave cycles per turn: 128 ... 8192 MHGE 200 B5 Through-hole hollow shaft with d= 50 ... 180 mm
Logic level: HTL, TTL Large permissible axial displacement
Max. output frequency: 300 kHz Large permissible air gap tolerance
Permissible encoder temperature: -40 °C up to +100 °C Option: additional incremental signals
Connection: 12 pole flange socket (ccw, pins)  
Vibration resistance (55 Hz ... 2000 Hz): 300 m/s²   
Shock resistance (2 ms): 3.000 m/s²   
Protection class: wheel IP 68 / head IP 67    
 
MHGE 400 B5 
Square-wave cycles per turn: 256 ... 16384 MHGE 400 B5 Through-hole hollow shaft with d= 100 ... 380 mm
Logic level: HTL, TTL Large permissible axial displacement
Max. output frequency: 300 kHz Large permissible air gap tolerance
Permissible encoder temperature: -40 °C up to +100 °C Option: additional incremental signals
Connection: 12 pole flange socket (ccw, pins)  
Vibration resistance (55 Hz ... 2000 Hz): 300 m/s²   
Shock resistance (2 ms): 3.000 m/s²   
Protection class: wheel IP 68 / head IP 67    
 
MHGE 800 B5 
Square-wave cycles per turn: 512 ... 32768 MHGE 800 B5 Through-hole hollow shaft with d= 380 ... 740 mm
Logic level: HTL, TTL Large permissible axial displacement
Max. output frequency: 300 kHz Large permissible air gap tolerance
Permissible encoder temperature: -40 °C up to +100 °C Option: additional incremental signals
Connection: 12 pole flange socket (ccw, pins)  
Vibration resistance (55 Hz ... 2000 Hz): 300 m/s²   
Shock resistance (2 ms): 3.000 m/s²   
Protection class: wheel IP 68 / head IP 67    
 
MHGP 100 B5 
Square-wave cycles per turn: 64, 128, ... 1024, ... 131072 MHGP 100 B5 Through-hole hollow shaft with d= 20 ... 80 mm
Logic level: HTL, TTL Large permissible axial displacement
Max. output frequency: 300 kHz Large permissible air gap tolerance
Permissible encoder temperature: -20 °C up to +85 °C Option: Error output
Connection: 12 pole flange socket (ccw, pins)  
Vibration resistance (55 Hz ... 2000 Hz): 300 m/s²   
Shock resistance (2 ms): 3.000 m/s²   
Protection class: wheel IP 68 / head IP 67    
 
MHGP 200 B5 
Square-wave cycles per turn: 128, 256, ... 1024, ... 262144 MHGP 200 B5 Through-hole hollow shaft with d= 50 ... 180 mm
Logic level: HTL, TTL Large permissible axial displacement
Max. output frequency: 300 kHz Large permissible air gap tolerance
Permissible encoder temperature: -20 °C up to +85 °C Option: Error output
Connection: 12 pole flange socket (ccw, pins)  
Vibration resistance (55 Hz ... 2000 Hz): 300 m/s²   
Shock resistance (2 ms): 3.000 m/s²   
Protection class: wheel IP 68 / head IP 67    
 
MHGP 400 B5 
Square-wave cycles per turn: 256, 512, 1024, ... 524288 MHGP 400 B5 Through-hole hollow shaft with d= 100 ... 380 mm
Logic level: HTL, TTL Large permissible axial displacement
Max. output frequency: 300 kHz Large permissible air gap tolerance
Permissible encoder temperature: -20 °C up to +85 °C Option: Error output
Connection: 12 pole flange socket (ccw, pins)  
Vibration resistance (55 Hz ... 2000 Hz): 300 m/s²   
Shock resistance (2 ms): 3.000 m/s²   
Protection class: wheel IP 68 / head IP 67    
 
 MHG 100  Download...
Square-wave cycles per turn: 64 - 1,024 MHG 100 Through-hole hollow shaft up to d= 80 mm
Maximum speed: 4,000 rpm
Logic level: HTL Tangential magnetic sensing
Permissible encoder temperature: -40 °C to +85 °C Large mounting tolerances 
Moment of inertia: approx. 17 kgcm?  
Shock resistance (12 ms): 2,000 m/s?   
Protection class: IP 68 Without own bearings
  
 MHG 150  Download...
Square-wave cycles per turn: 94 - 1,504 MHG 150 Through-hole hollow shaft up to d= 130 mm
Maximum speed: 4,000 rpm, Option: 12,000 rpm
Logic level: TTL Tangential magnetic sensing
Permissible encoder temperature: -40 °C to +85 °C Large mounting tolerances
Moment of inertia: approx. 18.4 kgcm? (d=130 mm, without marker pulse)
approx. 33.67 kgcm? (d=130 mm, with marker pulse)
Option: Marker pulse
 
Shock resistance (12 ms): 2,000 m/s?   
Protection class: IP 68 Without own bearings
  
 MHG 400  Download...
Square-wave cycles per turn: 256 - 2,048 MHG 400 Through-hole hollow shaft up to d= 380 mm
Maximum speed: 3,000 rpm
Logic level: HTL, TTL Operation possible under oil or water
Permissible encoder temperature: -20 °C to +95 °C Tangential magnetic sensing
Moment of inertia: approx. 1,118 kgcm? (d=380 mm) Large mounting tolerances
Shock resistance (12 ms): 2,000 m/s? Option: Special corrosion protection
Protection class: IP 68 Option: Cover  
    Without own bearings
  
Technical modifications reserved.

 